BM 6000


Home Map - Mappa



ELECTROPHYSIOLOGY UNIT

in compliance with ISCEV standard
 

 

Available version

BM6000-MINI indicated for small hospital center, studies

BM6000-MAXI indicated for research center

BM6000-Transportable indicated for ERG/VEP from flash transportable version

 

      

BM6000-MAXI

 

BM6000-MINI

BM6000-TRANSPORTABLE

 

 

  • Personal computer
  • Printer
  • Insulated transformer
  • Electrode and accessories

 

 

BM6000 MAXI BM6000-MINI BM6000-Trasportable
Amplif. BM623 4 ch. Amplif. BM629 4 ch. Amplif. BM629 4 ch.
Ganzfeld dome BM6007L Ganzfeld dome BM6007G Ganzfeld dome BM6007B
Pattern stimulator BM1610P with 17" monitor Pattern stimulator BM1612P with 17" monitor Software WinAverager
Software WinAverager Software WinAverager
Software WinEOG Software WinEOG

 

TECHNICAL INFORMATION

BM6000 MAXI

BM6000 MINI

BM6000-Trasportable

STANDARD EXAMINATIONS 

ERG

Rod response
ERG Maximal Combined Response
PO Oscillatory Potentials
ERG Single flash cone response

ERG

30 Hz Flicker response

VEP

Flash and Pattern Visual Evoked Potential

PERG

Pattern Electroretinogram

EOG Electrooculogram "Arden Ratio" Not available
HARDWARE
- Acquisition channels 4  / 16 bits resolution
- Amplifier

BM623

gain from 100 to 100.000 V/V.

filtering (analog): hi-pass from D.C. to 2 kHz

 low-pass from 2 Hz to 20 kHz

BM629

gain from 100 to 1.000.000 V/V.

filtering (digital): hi-pass from D.C. to 2 kHz

 low-pass from 2 Hz to 20 kHz

- Impedenziometer for electrode impedance measurement standard
- Test signal standard
- VISUAL PATTERN STIMULATOR

Mod. BM1610P

17" CRT Monitor - horizontal frequency 69 kHz - vertical frequency 85 Hz.

Mod. BM1612P

17" CRT Monitor - horizontal frequency 69 kHz - vertical frequency 85 Hz.

(Optional) Mod. BM1612P

17" CRT Monitor - horizontal frequency 69 kHz - vertical frequency 85 Hz.

- FLASH GANZFELD STIMULATOR

Mod. BM6007L

stimulation frequency up to 100 Hz, flash intensity from -3.5 to +1 U.L. (S.F. 3 cd/m2/sec.) in 0.25 U.L. steps. Background intensity from 0 to 600 cd/m2, EOG LEDs at 0°,30° and 45°, dome diameter 40 cm, stimulation an background optical filter insertion.

Mod. BM6007G

stimulation frequency up to 100 Hz, flash intensity from -3.5 to +1 U.L. (S.F. 3 cd/m2/sec.) in 0.25 U.L. steps. Background intensity from 0 to 600 cd/m2, EOG LEDs at 0° and 30° , dome diameter 30 cm.

Mod. BM6007B

stimulation frequency up to 100 Hz, flash intensity from -3,5 to +0.5 U.L. (S.F. 3 cd/m2/sec.) in 0.25 U.L. steps. Background intensity 30 cd/m2, central LED for patient fixation, dome diameter 20 cm.

 

(Optional)

- FLASH STIMULATOR

Mod. BM6007B9.5

stimulation frequency up to 100 Hz, flash intensity from -3,5 to +1.5 U.L. (S.F. 3 cd/m2/sec.) in 0.25 U.L. steps. Background intensity up to 600 cd/m2, dome diameter 9.5 cm.

 
- PC with colour monitor, HD,CD-RW, s.o. Microsoft Windows
- PRINTER Ink jet A4
- INSULATION TRANSFORMER 0.6KVA
SOFTWARE AVERAGER and EOG
- Keyboard driven parameters of stimulation, amplification, acquisition
- Standard protocols for each examination for fast routine work
- Manual and automatic cursors positioning
- Fourier analysis direct and inverse with amplitude and phase measurements
- Patient file and storage on hard disk or CD/DVD
- Single acquisition with off line averaging
- Acquisition point numbers up to 16384
- Analysis time from 10 ms to 100 s
- Report and data output for statistical analysis
 

Printable version BM6000 MINI Stampa   BM6000 MAXI Stampa  BM6000 TRANSPORTABLE Stampa

QUALITY AND SAFETY IN COMPLIANCE WITH MDD 93/42/ECC (download declaration )

Any details given in these document are subject to change without notice.

 

PRICE LIST BM6000 MINI

PRICE LIST BM6000 MAXI

PRICE LIST BM6000-Transportable

 

 


You can send an e-mail for questions or comments on this Web site . Potete inviare un messaggio di posta elettronica contenente domande o commenti su questo sito web.

 
Copyright © 2000-2012 Biomedica Mangoni s.n.c..
 
All rights reserved. Reproduction in whole or in part of any text, video, graphic, or audio materials on this Internet site, in any form or medium, without express written permission from Biomedica Mangoni s.n.c. is strictly prohibited.
 
Last Updated: 04/30/2015